Equine Reproductive Procedures. Группа авторов
Чтение книги онлайн.

Читать онлайн книгу Equine Reproductive Procedures - Группа авторов страница 75

Название: Equine Reproductive Procedures

Автор: Группа авторов

Издательство: John Wiley & Sons Limited

Жанр: Биология

Серия:

isbn: 9781119555933

isbn:

СКАЧАТЬ

       The mare’s rectum is evacuated and her perineum prepared routinely for a clean vaginal procedure (see Chapter 3).

       Using a sterile obstetrical sleeve and sterile lube, a 1 m flexible endoscope is advanced through the cervix and the uterus insulflated with air.

       The scope is passed up to the tip of one horn and the papilla at the utero‐tubular junction is identified (Figure 32.1).

       The catheter is fed through the injection port of the endoscope and, with the assistance of the guidewire, the orifice of the papilla is cannulated and the catheter is advanced over the wire and seated in place a few millimeters into the oviductal papilla (Figure 32.2).

       The guidewire is withdrawn, and a 20 gauge 4 cm (1.5 inch) needle attached to a syringe with 10 ml of LRS is secured onto the opposite end of the catheter. Fluid is then pulsed through the tube and into the oviduct. Note: it is not uncommon to experience significant resistance when pulsing fluid through the oviduct. This can be counteracted by gentle rotation and slight withdrawal and advancement of the catheter system until fluid flows more freely. Movements should be relatively fine to avoid unseating the catheter.

       The procedure is repeated on the contralateral oviductal papilla.

       The uterus is lavaged with LRS (see Chapter 34) at the conclusion of the procedure and once daily for 2–3 subsequent days.

       Prostaglandin F2α is administered intramuscularly to bring the mare back into estrus and allow her to clean out any contamination.

Photo depicts hysteroscopic view of hydrotubation of the uterine tubes. The guidewire has been advanced a few millimeters from the distal tip of the catheter to facilitate cannulation of the orifice of the uterine tube papilla.

      The oviduct is an important link between the ovary and uterus, and is the site of fertilization in vivo. Past research has shown that oviductal masses are not uncommon in mares, but the extent to which these masses can block or interfere with fertilization is unknown and likely only affects a small subset of mares. An accurate diagnosis of oviductal obstruction is difficult, and a presumptive diagnosis is often made by excluding other causes of subfertility. Consequently, diagnosis is often foregone and treatment is instead pursued to resolve potentially blocked oviducts.

Photo depicts hysteroscopic view of the hydrotubation procedure with the catheter seated in the uterine tube papilla.

      1 Bradecamp EA, Schnobrich MR. 2016. Hysteroscopic hydrotubation of the oviducts as a treatment for idiopathic infertility in the mare – a retrospective study. Proc Annu Conv Soc Theriogenol 8(3): 337.

      2 Inoue Y. 2013. Hysteroscopic hydrotubation of the equine oviduct. Eq Vet J 45: 761–5.

      3 Inoue Y, Sekiguchi M. 2017. Clinical application of hysteroscopic hydrotubation for unexplained infertility in the mare. Eq Vet J 50: 470–3.

       Claire E. Card

       Western College of Veterinary Medicine, University of Saskatchewan, Canada

      Alternative procedures to TVOB to ascertain the nature of an ovarian abnormality include laparoscopic ovarian biopsy and ovariectomy. Ovariectomy is irreversible and may limit fertility.

      Equipment and Supplies

      Tail wrap, tail rope, non‐irritant soap, roll cotton, stainless steel bucket, paper towels, exam gloves, sterile surgery gloves, sterile rectal sleeves, sterile lubricant, sedation, sterile towel, 14 g × 65 cm (25.5 inch) biopsy instrument, convex or linear array transvaginal ultrasound probe (7.5 or 10 mHz) self‐contained or with a housing, 70% isopropyl alcohol, sterile saline, formalin, sample vials, sterile glass slides, pencil, sedation, N‐butylscopolammonium bromide.

       The self‐contained probe should be wiped with 70% isopropyl alcohol. The biopsy channel should be similarly cold sterilized and then rinsed with sterile saline or a sterile pipette should be inserted into the biopsy channel so the biopsy instrument does not contact an unclean surface.

       If ultrasound probe housing is used it should be cold sterilized for a minimum of 10 minutes and the solution vigorously rinsed off with sterile water. The probe to be inserted in the housing should be wiped with 70% isopropyl alcohol and the unit assembled using sterile gloves.

       The distal 10 cm (4 inch) of the biopsy instrument should be cold sterilized with the sample notch exposed. The immersed end of the biopsy instrument should be rinsed with sterile saline and the remaining needle length and handle wiped with 70% isopropyl alcohol or disinfectant wipes and placed on a sterile towel.

       Place the mare in stocks to provide adequate restraint from lateral movement.

       Wrap the tail and remove feces from the rectum (see Chapter 4). Administer N‐butylscopolammonium bromide at 0.15 mg/kg slowly IV to relax the rectum.

       Tie the mare’s tail to the side, and remove the feces. Perform an ultrasound СКАЧАТЬ