Название: Process Gas Chromatographs
Автор: Tony Waters
Издательство: John Wiley & Sons Limited
Жанр: Отраслевые издания
isbn: 9781119633013
isbn:
6 S6. If the propane peak has a retention time of sixty seconds on a three‐meter column and propane has a solubility in the column liquid phase of 50 %, what is the average velocity of the carrier gas?Express your answer in m/s.
7 S7. Why do peaks that are evenly spaced in the column turn out to be unevenly spaced on the chromatogram? Combine two of the arguments given below to get the best overall explanation.Select two:All of the peaks spend the same time in the carrier gas.The later peaks are more soluble in the liquid phase than the earlier peaks are.After the air peak reaches the end of the column, the later peaks have farther to go than the earlier peaks do.The later peaks migrate through the column more slowly than the earlier peaks do.
8 S8. This question asks you to make logical deductions beyond what you learned in the chapter.Assuming that all other variables can be held constant, evaluate whether each statement listed below is true or false.Select all of the true statements and none of the false statements:The holdup time would be proportional to the column length.The retention time of a component peak would be proportional to the column length.If the carrier gas flow increased, the holdup time would increase.If the column temperature increased, the adjusted retention time of a component peak would decrease.None of the statements A−D above are true.
9 S9. This question asks you to make logical deductions beyond what you learned in the chapter.Consider a column that loses some of its stationary phase due to slow evaporation, but all other variables are held constant. Then, evaluate whether each statement listed below is true or false.Select all of the true statements and none of the false statements:The holdup time would be reduced.The retention time of all peaks would be reduced.The adjusted retention time of all peaks would be reduced.The separation of component peaks would be increased.None of the statements A−D above are true.
References
1
Figures
1 3.1 Effect of Component Solubility
2 3.2 Draw Your Own Chromatogram
3 3.3 Significance of the Air Peak
4 3.4 Typical Chromatogram Measurements
Equations
3.1 |
|
Average carrier gas velocity |
3.2 | tR = tM + t′R | Retention time as sum of times in gas and liquid phases |
3.3 |
|
Plate number from base width |
3.4 |
|
Plate number from width at half height |
3.5 |
|
Plate height (usually expressed in mm) |
Symbols
H | Plate height |
L | Column length |
N | Plate number |
t R | Peak retention time |
|
Peak adjusted retention time |
t M | Holdup time (air peak) |
w b | Peak base width |
w 0.5 | Peak width at half height |
u M | Average carrier gas velocity |
New technical terms
When first introduced, these words and phrases were shown in bold type. You should now know the meaning of these technical terms. If in doubt, consult the Glossary at the end of the book:
1 adjusted retention time
2 air peak
3 base width
4 holdup time
5 migration rate
6 triangulating
7 unretained peak
8 width at half height