Coal-Fired Power Generation Handbook. James G. Speight
Чтение книги онлайн.

Читать онлайн книгу Coal-Fired Power Generation Handbook - James G. Speight страница 15

Название: Coal-Fired Power Generation Handbook

Автор: James G. Speight

Издательство: John Wiley & Sons Limited

Жанр: Техническая литература

Серия:

isbn: 9781119510130

isbn:

СКАЧАТЬ global demand for electricity will continue to rise steeply until at least 2040, as the fuels used for electricity generation continue to shift to lower-carbon sources, such as natural gas, nuclear and renewables. Even now, the demand for electricity continues to rise in all parts of the world. Population and economic growth are two main reasons, just as they are for the projected demand growth in other fuels. There is a switch to electricity from other forms of energy, such as oil or biomass for lighting and heating in the home, or coal in the industrial sector. The key to this growing demand is to make electricity generation more efficient than is currently observed.

      As a result of current trends in the electric power market, many coal-fired generators in the United States are slated for retirement (Energy Information Administration, 2010, 2011, 2012a, 2012b). Most of the coal-fired power plants projected to retire are older, inefficient units primarily concentrated in the Mid-Atlantic, Ohio River Valley, and southeastern United States where excess electricity generating capacity currently exists. Lower natural gas prices, higher coal prices, slower economic growth, and the implementation of environmental rules all play a role in the retirements. Coal-fired generators in these regions, especially older, less efficient ones that lack pollution control equipment, are sensitive to changing trends in fuel prices and electricity demand, which are two key factors that influence retirement decisions.

      The coal-fired power plants vulnerable to retirement are older power plants generators with high heat rates (lower efficiency) that do not have flue gas desulfurization (FGD) systems installed. Approximately 43% of all coal-fired plants did not have flue gas desulfurization systems installed as of 2010 and such plants will be required to install either a FGD or a dry sorbent injection system to continue operating in compliance with the mercury and air toxics standards (MATS).

      Coal capacity retirements are sensitive to natural gas prices. Lower natural gas prices make coal-fired generation less competitive with natural gas-fired generation. Because natural gas is often the marginal fuel for power generation, lower natural gas prices also tend to reduce the overall wholesale electricity price, further reducing revenues for coal-fired generators.

      Installation of environmental control systems will add internal energy requirements, reducing the efficiency of the plant. There are some changes that can be employed to make an existing unit more efficient. However, these changes typically will only result in an improvement to efficiency of a percentage point or so. In order to produce higher efficiency ratings, higher pressure and temperatures are required. This increases the cost of the plant as special alloy materials will be needed. Technology improvements can assist by lowering the cost of these special materials through discovery and better manufacturing process.

      Electricity generation in a coal-fired power station requires combustion of the coal, after which the energy released during the combustion is used to generate steam which is then used to drive the turbine generators that produce electricity. The power station can be conveniently divided in four separate but, in reality, integrated operations: (i) the combustor or firebox, (ii), the boiler, (iii) the turbine generator, and (iv) the condenser.

      Before the coal is burned in the combustor, it is pulverized (often to an extremely small size that has been stated to have the appearance of a black talcum powder) after which the coal is mixed with hot air and blown into the combustor. The coal is burned in suspension and provides the most complete combustion and maximum heat possible.

      In the boiler, purified water is pumped through pipes inside the boiler which converts the water to steam. At temperatures up to 540°C (1000°F) and under pressures up to 3500 psi, the steam is piped to the turbine where it contacts a series of turbine blades and turns the turbine shaft. The turbine shaft is connected to the shaft of the generator, where magnets spin within wire coils to produce electricity. The steam is then drawn into a condenser which condenses the steam back into water so that it can be used over and over again in the plant. Millions of gallons of cooling water are pumped through a network of tubes that runs through the condenser and after the steam is condensed, it is pumped to the boiler again to repeat the cycle.

      Coal quality is the term used to refer to the properties and characteristics of coal that influence its behavior and use. Coal quality has an impact on many parts of a power plant including the coal handling facilities, pulverizing mills, boiler, air heater, electrostatic precipitator, ash disposal as well as stack emissions. Because coals have different characteristics and heat content, the behavior of a coal in a boiler is strongly influenced by the rank of the coal as well as and by the content (and type) of the mineral matter and other impurities associated with it. Coal properties can affect the efficiency, reliability, and availability of both the boiler and the emissions control units, and therefore, the properties affect the economics as well as the short- and long-term operation of the plant.

      Among the coal-quality characteristics that are important for coal-fired power plants are the concentrations, distribution, and forms of the many elements contained in the coal feedstock. Knowledge of these quality characteristics in coal deposits may allow us to use this essential energy resource more efficiently and effectively and with less undesirable environmental impact.

      In fact, the performance of power plants and the costs of power generation are influenced by many coal properties. Specifically, coal quality impacts not only coal cost but also net power output as well as capital and operating and maintenance costs and waste disposal costs. In fact, coal quality impacts the coal chain in a power plant and their relationship to power generation costs.

      Thus, an essential part of power plant development is the rigorous analysis of information which should be internally consistent and verifiable, such as coal quality, coal consumption and electricity output. It is, therefore, necessary to understand operating information for units at coal-fired power plants not only for the purposes of determining, monitoring, reporting, comparing, and projecting coal-fired power plant efficiencies but also for monitoring carbon dioxide emissions (as well as the emission of other noxious gases and particulate matter).

      Thus, to develop combustion technology for efficient production of electricity, the influences of the coal properties, such as the (i) the elemental composition of the coal, (ii) rank of the coal, the mineral matter content of the coal, (iii) the size of the pulverized coal particles, and (iv) the tendency of the combustion system to produce fly ash and bottom slag are all of considerable importance and need to be addressed in assessing the potential performance of a coal-fired electricity generating plant.

Rank Description
Lignite The largest portion of the coal reserves of the world. A soft, brownish-black coal which is the lowest level of the coal family. The texture of the original wood can even be seen in some pieces primarily found west of the Mississippi River.
Subbituminous coal A dull black coal which, when burned, СКАЧАТЬ